SZS Oil/Gas Fired Boiler
Get a quotation
SZS Oil/Gas Fired Boiler
Capacity : 4-80t/h
Pressure : 1.0-2.45MPa

Brief Intro:

SZS series oil/gas fired boiler adopts staged combustion and advanced technology. SZS boilers have high safety and thermal efficiency as high as 98%, which not only achieves ultra-low nitrogen emissions, but also greatly saves energy, making them become the first choice for customers in various industries.

Introduction:

The body of the SZS series boiler is a double-drum, chamber-fired D-type layout structure, the right side is the furnace, and the left side is the convection tube bundle. It is fixed on the body chassis through the movable supports in the middle and at both ends of the lower drum, and ensures that the boiler as a whole expands to both ends. The furnace is surrounded by narrow-spaced tube-film water-cooling walls, and the membrane-type water-cooling wall on the left side of the furnace completely seals and separates the furnace from the convection tube bundle. The flue gas generated by the combustion of the furnace enters the burnout chamber and the convection tube bundle area from the smoke outlet at the rear of the furnace, and then turns from the front left side of the boiler to enter the spiral finned tube economizer and condenser, and finally enters The flue enters the chimney and is discharged to the atmosphere.

SZS type oil and gas fired boiler water wall and convection flue all adopt membrane wall structure, which has good sealing performance, high heat absorption rate, and effectively reduces the use and maintenance workload of refractory bricks. In addition, the boiler adopts high thermal resistance material as the thermal insulation layer, and the thermal insulation performance is good. An energy-saving condenser is arranged at the rear, which can effectively reduce the exhaust gas temperature, and the boiler thermal efficiency is high.

(a) The design of the large combustion chamber makes the fuel burn with high efficiency and low pollution.

(b) There is an explosion-proof door on the boiler, which can discharge the energy released by the explosion of the chamber.

(c) The rear section of such boiler is equipped with flue gas condensing and recovery device which can effectively control exhaust gas temperature so that to improve boiler thermal efficiency.

(a) The water supply adopts continuous electric adjustment and has the functions of high and low water level alarm and interlock protection.

(b) The boiler adopts a quick installation structure, which can effectively shorten the installation time.

Get An Instant Quotation

For all inquiries, please fill in the form below (* are required) to send us a brief message, and we will get back to you as soon as possible.

    Product:
    * Email:
    Tel:
    Name:
    Boiler fuel:
    Application: